The Comparation of Side Effect and Duration of Norplant Removal between U and Standard Technique (Perbandingan Pencabutan Norplant (R) : Teknik 'U' dan Teknik Biasa)
The purpose of the study was to compare side effects and duration of Norplant removal between 'U' and standard technique, with methods was a randomized controlled technique, with method was a randomized controlled clinical trial of acceptors of family planning clinic, Dr. Kariadi Hospital Semarang, who wanted to remove their norplant implants. The norplant implants removed providers who had been trained for both 'U' and standard removals technique. Duration of removal, physical condition of capsules, and complication were examined. The results showed that from 41 'U' technique and 41 standard technique removals: the mean duration of removals are 2.75 (1.28) and 6.57 (2.93) minutes (p less than 0.001): unbroken capsule completely removes 6.00 (0.0) and 5.78 (0.42) (p less than 0.01) respectively. No complication during removal; one week after there are hematoma 2.44 percent and 9.7 percent respectively. Two week afterwards the hematoma dissappeared without medication.
A00001145 | Available |
No other version available